HK-7100A 7200A PID Gas Leakage Detector

Applications: Chem or petrochemical, Gas Station, Paint Spray Booth, Oil and Gas Industry, Refining and Petrochemical, Underground Vaults, Indoor/Outdoor Air Quality
Supplies category:Photo Ionization Detector
Material code:Photo Ionization Detector
Manufacturer:HKY Technology Co.,Ltd.
Nhận báo giá Hotline Email PDF
×

Vui lòng để lại thông tin của bạn trước khi tải xuống sản phẩm PDF.

Lưu ý: Vui lòng đảm bảo bạn đã nhập đúng địa chỉ E-mail. Chúng tôi sẽ gửi cho bạn thông tin liên quan và báo giá sản phẩm thường xuyên.

Feature

. Advanced 32 bits MCU technology, fast data processing
. SMT design---compact and reliable
. Power by controller or individual power
. Ultra-bright OLED (Organic Light Emitting Diode) and wide range temperature display
. User-friendly interface:Chinese and English
. Unique magnetic pen
. bi-directional infrared remote controller
. General transmitter
. Intelligent sensors applicable for five detection principles, 
  hundreds kinds of gas and different detection range
  ---compatible and interchangeable
. Hot swap sensor, plug and play, fault diagnostics

Technique Data

 

Display

OLED(Organic Light Emitting Diode)

Two level alarms and fault alarm indicator

Operation

magnetic pen 

Measurement

Combustible/Toxic gas

Principle 

Photo Ionization

Sample Method

diffusion

Measurement Range

Upon customers’ requirement

Resolution

1×10-6

Accuracy

3% Full scale

Response Time (T90)

≤30 sec

Alarm Configuration

two levels alarm, the alarm concentration programmable

Ambient Temperature

(-40~70)oC

Ambient Humidity

≤93%RH (no condensation)

Atmosphere Pressure

(86~106) KPa

Output

(4~20)mA  + BUS(CAN、RS485、HART)(OPTIONAL)

Transmission

(4~20)mA and HART:≤1000m(2.5 mm2)

CAN BUS:         ≤10km

RS485 BUS:       ≤1.2km

Power Supply

DC24V±6V power by controller or individual power

Wiring

3-wire 4-wire

Power Consumption

≤5W

Storage Temperature

(-40~85)oC

Anti–explosion Marker

ExdⅡCT6

Protection Rating

IP66

Applicable Standard

GB15322.1-2003

Gas

Range

Volatile Organic Gases

20×10-6, 100×10-6, 200×10-6,

500×10-6, 1000×10-6, 2000×10-6

 

Note:

Isobutylene(10.6eV Ionization lamp) is the reference for ranges above, for ranges of other

gases, multiply the correction factors with range of Isobutylene.

 

Configure

. Audio and Visual alarm
. bi-directional infrared remote controller

Sản phẩm liên quan

Yêu cầu
Vui lòng gửi thông tin yêu cầu của bạn cho chúng tôi. Chúng tôi sẽ liên lạc ngay thời gian sớm nhất

Gửi liên hệ thành công. Chúng tôi sẽ phản hồi trong thời gian sớm nhất

Quá trình thực hiện không thành công. Vui lòng thử lại sau

Đối tác - Khách hàng

Xem thêm: yokogawa-vn.com

088.604.6088

latex clothing uk
latex catsuit
latex dress
latex dresses