. Advanced 32 bits MCU technology, fast data processing
. SMT design---compact and reliable
. Power by controller or individual power
. Ultra-bright OLED (Organic Light Emitting Diode) and wide range temperature display
. User-friendly interface:Chinese and English
. Unique magnetic pen
. bi-directional infrared remote controller
. General transmitter
. Intelligent sensors applicable for five detection principles,
hundreds kinds of gas and different detection range
---compatible and interchangeable
. Hot swap sensor, plug and play, fault diagnostics
|
Display |
OLED(Organic Light Emitting Diode) Two level alarms and fault alarm indicator |
|
Operation |
magnetic pen |
|
Measurement |
Combustible/Toxic gas |
|
Principle |
Photo Ionization |
|
Sample Method |
diffusion |
|
Measurement Range |
Upon customers’ requirement |
|
Resolution |
1×10-6 |
|
Accuracy |
3% Full scale |
|
Response Time (T90) |
≤30 sec |
|
Alarm Configuration |
two levels alarm, the alarm concentration programmable |
|
Ambient Temperature |
(-40~70)oC |
|
Ambient Humidity |
≤93%RH (no condensation) |
|
Atmosphere Pressure |
(86~106) KPa |
|
Output |
(4~20)mA + BUS(CAN、RS485、HART)(OPTIONAL) |
|
Transmission |
(4~20)mA and HART:≤1000m(2.5 mm2) CAN BUS: ≤10km RS485 BUS: ≤1.2km |
|
Power Supply |
DC24V±6V power by controller or individual power |
|
Wiring |
3-wire 4-wire |
|
Power Consumption |
≤5W |
|
Storage Temperature |
(-40~85)oC |
|
Anti–explosion Marker |
ExdⅡCT6 |
|
Protection Rating |
IP66 |
|
Applicable Standard |
GB15322.1-2003 |
|
Gas |
Range |
|
Volatile Organic Gases |
20×10-6, 100×10-6, 200×10-6, 500×10-6, 1000×10-6, 2000×10-6 |
Note:
Isobutylene(10.6eV Ionization lamp) is the reference for ranges above, for ranges of other
gases, multiply the correction factors with range of Isobutylene.
. Audio and Visual alarm
. bi-directional infrared remote controller
0888.755.860